ZGATE API Reference UM024502-1012
70
ZGATE Embedded Security Development Kit
User Manual
ZGATE_set_th_interval
Function Prototype
INT16 ZGATE_set_th_interval( INT32 Interval );
Parameters
Interval The threshold filtering interval duration, in seconds. The interval
must be at least 10 and no more than 1800 seconds.
Return Value
TRUE The threshold filtering interval was successfully changed.
FALSE The specified interval is invalid.
Description
ZGATE’s threshold filtering module constantly measures packet flow over a specific inter-
val of time to determine if the packet flow from a particular source has exceeded filtering
thresholds. This API is used to set the ZGATE threshold filtering interval.